Calculators / Doors

How many garage door insulation kits do you need?

One kit does a single 8 or 9 ft door, and a 16 or 18 ft double takes two, by the makers’ own counts. Put in your door to see every kit side by side, with the R-value each one claims.

Updated · How we check our numbers

These are example numbers. Put in yours.

Your door

ft

Standard: 8 or 9 ft for one car, 16 or 18 ft for two.

ft

7 ft is standard, 8 ft is the tall size.

rows

The horizontal sections the door folds at. Most 7 ft doors have 4.

Door
Insulated now?

Heating

°F

How much warmer you keep the garage than it is outside on a cold day.

Buy this many

2 kits

For a 16 x 7 ft door with 4 sections. Owens Corning claims R-8 for its fiberglass, the foam board kits R-4.6 to R-4.8, and Reach Barrier’s reflective kit no R-value at all.

Door
16 x 7 ft112 sq ft
Panel run
768 in4 sections x 192 in
Bare steel
5,271 BTU/hR 0.85, air films only
With an R-8 kit
506 BTU/hR 8.85, panels only
See garage door insulation kits on Amazon (opens Amazon in a new tab)

As an Amazon Associate we earn from qualifying purchases.

Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.

Size a heater for the garageThe door panels lose about 5,271 BTU/h bare and 506 with an R-8 kit at 40°F colder outside (panels only)

Check the opener for an insulated door16 x 7 ft, now an insulated steel door

panel run = 4 sections x 192 in = 768 in

54 in panels: 15 panels, 2 kits of 8

48 in panels (Reach Barrier): 16 panels, 2 kits of 8

heat through the panels at 40°F colder outside = 112 sq ft x 40 ÷ R

bare: ÷ 0.85 = 5,271 BTU/h; R-4.8 kit: ÷ 5.6499999999999995 = 793; R-8 kit: ÷ 8.85 = 506

Kits and what each maker says it covers

6 kits
  • Owens Corning Garage Door Insulation KitFiberglass, white vinyl facing, R-8 (ASTM C177). 8 panels 22 x 54 in. Maker: a single door up to 9 ft wide by 7 ft 4 in high.
    2 kits

    15 panels for 4 sections, 8 to a kit.

    See it on Amazon (opens Amazon in a new tab)
  • Matador Garage Door Insulation KitEPS foam board, R-4.8 at 75°F. 8 panels 20.3 x 54 in. Maker: single 8 and 9 ft metal doors; 2 kits for 16 and 18 ft.
    2 kits

    15 panels for 4 sections, 8 to a kit.

    See it on Amazon (opens Amazon in a new tab)
  • Cellofoam Garage Door Insulation KitEPS foam board, about R-4.6 at 75°F, R-5.0 at 40°F. 8 panels 20 x 54 in. Maker: 60 sq ft, a typical 9 ft wide door.
    2 kits

    15 panels for 4 sections, 8 to a kit.

    See it on Amazon (opens Amazon in a new tab)
  • Plymouth Foam Garage Door Insulation KitEPS foam board, R-4.8. 8 panels 20 x 54 in. Maker: standard 8 and 9 ft single metal doors; 2 kits for 16 and 18 ft.
    2 kits

    15 panels for 4 sections, 8 to a kit.

    See it on Amazon (opens Amazon in a new tab)
  • Insulfoam Garage Door Insulation KitEPS foam board, no R-value on its spec sheet. 8 panels 20.3 x 54 in. Maker: most standard 8 or 9 ft doors.
    2 kits

    15 panels for 4 sections, 8 to a kit.

    See it on Amazon (opens Amazon in a new tab)
  • Reach Barrier 3009 Garage Door Insulation KitReflective bubble, none: Reach Barrier says reflective insulation isn’t rated in R-value. 8 panels 24 x 48 in. Maker: no door size stated.
    2 kits

    16 panels for 4 sections, 8 to a kit.

    See it on Amazon (opens Amazon in a new tab)

R-values are what each maker claims for the material. Heat figures are the door panels only (DASMA’s section method); joints, stiles and seals let more through.

The R-value is the material’s, not the door’s

A kit’s R-value is for the panel itself. DASMA, the door makers’ association, says a door section’s R-value leaves out the joints between sections and the stiles, where heat takes a shortcut around the insulation, and that only a tested U-factor describes a whole door. The steel adds nothing (DASMA counts metal facings as zero). So an R-8 kit doesn’t make an R-8 door.

Measure the openings first

Your sections are about 21 in tall. Kit panels are 20 to 24 in tall and get cut to length. Measure the opening between the rails on one section before you buy.

It adds weight

Matador puts a kit at about 10 lb and Plymouth Foam at 9.5 lb. That weight hangs on the springs.

How we work it out

Every kit we found has 8 panels, and you cut each one to fit between the rails on the back of the door. Each section takes a row of panels as long as the door is wide, and offcuts carry over.

panels = sections × door width ÷ panel length, rounded up

kits = panels ÷ 8, rounded up

On a 4-section door that gives 1 kit for 8 and 9 ft doors and 2 kits for 16 and 18 ft. That matches the makers: Owens Corning, Cellofoam, Matador and Plymouth Foam put one kit on a 9 ft door, and Matador and Plymouth Foam say two for a 16 or 18 ft door. Reach Barrier's panels are 48 in long, not 54, so a 9 ft door takes a second kit.

  • 8 x 7 ft (single, standard): 1 kit of 54 in panels, 1 kit of 48 in
  • 9 x 7 ft (single, standard): 1 kit of 54 in panels, 2 kits of 48 in
  • 10 x 7 ft (single, wide): 2 kits of 54 in panels, 2 kits of 48 in
  • 9 x 8 ft (single, tall (trucks and vans)): 1 kit of 54 in panels, 2 kits of 48 in
  • 16 x 7 ft (double, standard): 2 kits of 54 in panels, 2 kits of 48 in
  • 16 x 8 ft (double, tall): 2 kits of 54 in panels, 2 kits of 48 in
  • 18 x 7 ft (double, wide): 2 kits of 54 in panels, 3 kits of 48 in
  • 20 x 8 ft (double, extra wide): 3 kits of 54 in panels, 3 kits of 48 in

The R-value on the box is the panel's. Owens Corning claims R-8 for its fiberglass. The foam board kits claim R-4.6 to R-4.8 at 75°F. Reach Barrier says reflective insulation isn't rated in R-value at all.

It isn't the door's R-value. DASMA, the door makers' association, says a door section's R-value leaves out the joints between sections and the stiles, where heat gets around the insulation, and that only a tested U-factor describes a whole door. So we work out heat through the panels only, with DASMA's numbers: 0.85 for the air on both faces, and nothing for the steel.

heat (BTU an hour) = door area × degrees colder outside ÷ (0.85 + kit R-value)

That's the most a kit can save. The real door loses more, through the joints, the edges and the seals. Owens Corning says its kit gives "5x better thermal performance" than an uninsulated door.